Ceka Revax Axial & Inverted Axial

Ceka Revax Axial & Inverted Axial
Ceka Revax Axial & Inverted Axial

M3: OL 895TI Inverted Axial
Titanax female for bonding in the casting with Ceka Site.
Titanax retention part for retaining in acrylic resin.

Benefits:

  • Casting (coping or bar) may be in any alloy
  • No miscast or devesting errors. The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

M2: RE 795TI     Inverted Axial     Reduced Size
Titanax female for bonding in the casting with Ceka Site.
Titanax retention part for retaining in acrylic resin.

Benefits:

  • Casting (coping or bar) may be in any alloy
  • No miscast or devesting errors. The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

M3: OL 885TI     Inverted Axial
Titanax female for bonding in the casting with Ceka Site.
Retention part for the bonding technique, also with Ceka Site.

Benefits:

  • Casting (coping or bar) may be in any alloy
  • No miscast or devesting errors. The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • Provides option to veneer directly to the removable partial denture metal frame for improved esthetics. The first tooth of the removable partial denture looks like a tooth and blends with the abutment crowns.
  • The Spacer (bonding) retention system is very technique sensitive, and the instructions must be thoroughly followed.

M2: RE 785TI     Inverted Axial     Reduced Size
Titanax female for bonding in the casting with Ceka Site.
Retention part for the bonding technique, also with Ceka Site.

Benefits:

  • Casting (coping or bar) may be in any alloy
  • No miscast or devesting errors. The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • Provides option to veneer directly to the removable partial denture metal frame for improved esthetics. The first tooth of the removable partial denture looks like a tooth and blends with the abutment crowns.
  • The Spacer (bonding) retention system is very technique sensitive, and the instructions must be thoroughly followed.

M3: OL 861TI     Inverted Axial
Titanax female for bonding in the casting with Ceka Site.
Retention part for soldering.

Benefits:

  • Casting (coping or bar) may be in any alloy
  • No miscast or devesting errors. The accurate titanium female insert is bonded in after all other procedures are completed.
  • The abutment crowns and female attachment may be altered if necessary after try-in.
  • A strong solder connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

M2: RE 761TI     Inverted Axial
Titanax female for bonding in the casting with Ceka Site.
Retention part for soldering.

Benefits:

    • Casting (coping or bar) may be in any alloy
    • No miscast or devesting errors. The accurate titanium female insert is bonded in after all other procedures are completed.
    • The abutment crowns and female attachment may be altered if necessary after try-in.
    • A strong solder connection to the cast metal frame is used when vertical space is limited, or the patient exhibits a very strong bite.

M3: 691TI     Traditional Axial
Pallax base ring for soldering to the post coping or bar.
Titanax female for retention in acrylic resin.

Benefits:

  • Male on the post coping or bar for more prosthesis stability.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

M2: RA 61 TI     Traditional Axial     Reduced Size
Pallax base ring for soldering to the post coping or bar.
Titanax female for retention in acrylic resin.

Benefits:

  • Male on the post coping or bar for more prosthesis stability.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

M3: 693TI     Traditional Axial
Irax base ring for direct casting with precious metal and palladium based alloys, or for soldering to the post coping.
Titanax female for retention in acrylic resin.

Benefits:

  • Male on the post coping or bar for more prosthesis stability.
  • The ease of direct casting.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth

M2: RA 63 TI     Traditional Axial     Reduced Size
Irax base ring for direct casting with precious metal and palladium based alloys, or for soldering to the post coping.
Titanax female for retention in acrylic resin.

Benefits:

  • Male on the post coping or bar for more prosthesis stability.
  • The ease of direct casting.
  • The acrylic retention cap may be easily removed (use heat) from the prosthesis and replaced or repositioned if necessary.
  • Clinical/Intra-oral: the acrylic retention cap is easily connected to a cast frame in the mouth
  • Clinical/Intra-oral: the acrylic retention cap may be easily picked up in the mouth